The single-phase pad-mounted transformer rated capacity is 15-250 kVA. Single-phase Pad-mounted Transformer is generally used in places where single-phase power is required for civil use, such as household appliances, etc., and its capacity is relatively smaller than a three-phase pad-mounted transformer.
  • Product Description
    • Single Phase Pad Mounted Transformer

    • Primary Voltage Ratings: 34.5kV/19.92kV, 24.94kV/14.4kV, 13.8kV/7.957kV, 13.2kV/7.62kV, 12.47kV/7.2kV or others

    • Secondary Voltage Ratings: 120/240V, 240/480V, 347V, 600V or others

    • H.V. TAP RANGE: ±2×2.5% or others

    • CONNECTION TYPE: Delta/Wye

    • TYPE: Loop feed/Radial feed

    • BIL: 30-150

    • Standards: ANSI, IEEE, 

    • Application: Residential Areas, Hotels, Single Family Houses, Parks, Underground Distribution Systems

    • Power Rating: 15-250 kVA

    The single-phase pad-mounted transformer rated capacity is 15-250 kVA. 

    Single-phase Pad-mounted Transformer is generally used in places where single-phase power is required for civil use, 

    such as household appliances, etc., and its capacity is relatively smaller than a three-phase pad-mounted transformer.


    Single-phase Pad-mounted Transformer Specification

    Single phase Pad mounted Transformer Specification
    Rating
    (kVA)
    High voltage(kV) No Load Loss On load Loss Height
    (mm)
    Depth
    (mm)
    Width
    (mm)
    Oil Weight(kg) Total Weight(kg)
    15 kVA 34.5/19.92
    13.8/8
    13.2/7.6
    12.47/7.2
    or others
    50 195 840 740 610 45 294
    25 kVA 80 290 840 740 610 68 362
    37.5 kVA 106 360 840 760 610 75 476
    50 kVA 135 500 840 810 610 93 553
    75 kVA 190 650 840 860 610 132 672
    100 kVA 280 1010 910 1200 965 230 714
    167 kVA 435 1530 1000 1200 965 265 913
    250 kVA 550 2230 1250 1300 1430 325 1106


    Product structure diagram


    daelim-single-phase-padmounted-transformer.jpg


    OPTIONAL ACCESSORIES

    •  Multiple voltages or taps

    • Externally operable multiple voltages or tap changer switches for

    safe operation

    •  Stainless steel tank, tank bottom, sill, door, and/or hardware

    •  Service entrance in the sill

    •  Various spades and terminals available for secondary bushings

    •  Various other designations available, e.g., kVA, voltages, fuse number

    •  High-voltage bushing inserts

    •  Ground connectors

    • One piece high-voltage bushings

    •Envirotemp™ FR3™ fluid

    • Load break switches

    • Drain/sampling valve

    • Pressure vacuum gauge

    • Liquid level gauge

    • Temperature gauge

    • Canadian Standards Association (CSA) and Consumer Electronics Association (CEA) design stage bushing


    DESIGN PERFORMANCE TEST

    The design performance tests include the following:

    • Temperature Rise: Our automated heat run facility ensures that any design changes meet ANSI® and IEEE® temperature rise criteria.

    • Audible Sound Level: Ensures compliance with NEMA® requirements.

    • Lightning Impulse: To assure superior dielectric performance, this test consists of one reduced wave, two chopped waves, and one full wave in sequence, precisely simulating the harshest conditions.

    • The performance tests such as short-circuit capability tests, and lifting and moving devices tests can be executed while specified by the customer.